Product catalogue / 05

Overfill Prevention & Grounding Equipment

High-level detection and grounding supervision. Confirm electrical compatibility and system logic before combining field components.

13 traceable product codes

Product models and configurations

SIMEI FT-OP-100 — Optical overfill sensor
SIMEI FT-OP-100

Optical overfill sensor

Mounted on a fuel tanker to monitor the internal liquid level during bottom loading in cooperation with the loading-platform control system.

Technical details

Main features

  • Detects liquid level during bottom loading and sends the signal to the loading-platform system.
  • Designed to support bottom-loading overfill prevention.
  • Probe length and material can be specified to suit the application.

Available Configurations

  • Application-specific probe length and material

Technical & Ordering Data

Working voltage12 VDC
Working current<5 mA
Response time<1 s
Temperature range−20°C to +50°C
Working mediumLight fuel
Probe lengthMade to user requirement; confirm length
Seal materialConfirm before quotation
Body materialConfirm before quotation

Confirm Before Order

  • Confirm mounting connection, overall probe length, wiring and controller compatibility.
  • Any required hazardous-area protection, including the source-listed Ex ia IIB T4 designation, requires valid documentation for the actual SIMEI supply.

Engineering Note

A sensor is part of an overfill-protection system; the complete wiring, controller and loading-platform interface must be matched.

SIMEI FT-OP-110 — Stainless-steel optical overfill sensor
SIMEI FT-OP-110

Stainless-steel optical overfill sensor

Mounted on a fuel tanker to monitor the internal liquid level during bottom loading in cooperation with the loading-platform control system.

Technical details

Main features

  • Detects liquid level during bottom loading and sends the signal to the loading-platform system.
  • Designed to support bottom-loading overfill prevention.
  • Probe length and material can be specified to suit the application.

Available Configurations

  • Application-specific probe length and material

Technical & Ordering Data

Working voltage12 VDC
Working current<5 mA
Response time<1 s
Temperature range−20°C to +50°C
Working mediumLight fuel
Probe lengthMade to user requirement; confirm length
Seal materialConfirm before quotation
Body materialStainless steel

Confirm Before Order

  • Confirm mounting connection, overall probe length, wiring and controller compatibility.
  • Any required hazardous-area protection, including the source-listed Ex ia IIB T4 designation, requires valid documentation for the actual SIMEI supply.

Engineering Note

A sensor is part of an overfill-protection system; the complete wiring, controller and loading-platform interface must be matched.

SIMEI FT-OP-120 — Optical overfill sensor
SIMEI FT-OP-120

Optical overfill sensor

Mounted on a fuel tanker to monitor the internal liquid level during bottom loading in cooperation with the loading-platform control system.

Technical details

Main features

  • Detects liquid level during bottom loading and sends the signal to the loading-platform system.
  • Designed to support bottom-loading overfill prevention.
  • Probe length and material can be specified to suit the application.

Available Configurations

  • Application-specific probe length and material

Technical & Ordering Data

Working voltage12 VDC
Working current<5 mA
Response time<1 s
Temperature range−20°C to +50°C
Working mediumLight fuel
Probe lengthMade to user requirement; confirm length
Seal materialConfirm before quotation
Body materialConfirm before quotation

Confirm Before Order

  • Confirm mounting connection, overall probe length, wiring and controller compatibility.
  • Any required hazardous-area protection, including the source-listed Ex ia IIB T4 designation, requires valid documentation for the actual SIMEI supply.

Engineering Note

A sensor is part of an overfill-protection system; the complete wiring, controller and loading-platform interface must be matched.

SIMEI FT-OP-130 — Optical overfill sensor probe
SIMEI FT-OP-130

Optical overfill sensor probe

Replacement or application-specific optical probe for the tanker bottom-loading overfill-prevention system.

Technical details

Main features

  • Detects liquid level during bottom loading and sends the signal to the loading-platform system.
  • Designed to support bottom-loading overfill prevention.
  • Probe length and material can be specified to suit the application.

Available Configurations

  • Single straight probe with loose wire leads.
  • Probe length and material to user requirement

Technical & Ordering Data

Working voltage12 VDC
Working current<5 mA
Response time<1 s
Temperature range−20°C to +50°C
Working mediumLight fuel
Probe lengthMade to user requirement; confirm length
Seal materialConfirm before quotation
Probe materialConfirm before quotation
Electrical ratingsThe adjacent optical-sensor family table is the only table; confirm applicability to the selected bare probe.

Confirm Before Order

  • Confirm probe length, sensing tip, cable length, wiring, mounting and matched controller.
  • Confirm the 12 VDC / <5 mA family ratings for the selected probe.
  • Hazardous-area suitability must be documented for the actual supplied probe; the family source lists Ex ia IIB T4.

Engineering Note

Bare probes are individually pictured, but the source gives no variant-specific dimensions, wiring diagram or separate electrical table.

SIMEI FT-OP-140 — Optical overfill sensor probe
SIMEI FT-OP-140

Optical overfill sensor probe

Replacement or application-specific optical probe for the tanker bottom-loading overfill-prevention system.

Technical details

Main features

  • Detects liquid level during bottom loading and sends the signal to the loading-platform system.
  • Designed to support bottom-loading overfill prevention.
  • Probe length and material can be specified to suit the application.

Available Configurations

  • Two probe lengths are shown under the same source model.
  • Probe length and material to user requirement

Technical & Ordering Data

Working voltage12 VDC
Working current<5 mA
Response time<1 s
Temperature range−20°C to +50°C
Working mediumLight fuel
Probe lengthMade to user requirement; confirm length
Seal materialConfirm before quotation
Probe materialConfirm before quotation
Electrical ratingsThe adjacent optical-sensor family table is the only table; confirm applicability to the selected bare probe.

Confirm Before Order

  • Confirm probe length, sensing tip, cable length, wiring, mounting and matched controller.
  • Confirm the 12 VDC / <5 mA family ratings for the selected probe.
  • Hazardous-area suitability must be documented for the actual supplied probe; the family source lists Ex ia IIB T4.

Engineering Note

Bare probes are individually pictured, but the source gives no variant-specific dimensions, wiring diagram or separate electrical table.

SIMEI FT-OP-150 — Optical overfill sensor probe
SIMEI FT-OP-150

Optical overfill sensor probe

Replacement or application-specific optical probe for the tanker bottom-loading overfill-prevention system.

Technical details

Main features

  • Detects liquid level during bottom loading and sends the signal to the loading-platform system.
  • Designed to support bottom-loading overfill prevention.
  • Probe length and material can be specified to suit the application.

Available Configurations

  • Straight probe with trailing leads and dark sensing tip.
  • Probe length and material to user requirement

Technical & Ordering Data

Working voltage12 VDC
Working current<5 mA
Response time<1 s
Temperature range−20°C to +50°C
Working mediumLight fuel
Probe lengthMade to user requirement; confirm length
Seal materialConfirm before quotation
Probe materialConfirm before quotation
Electrical ratingsThe adjacent optical-sensor family table is the only table; confirm applicability to the selected bare probe.

Confirm Before Order

  • Confirm probe length, sensing tip, cable length, wiring, mounting and matched controller.
  • Confirm the 12 VDC / <5 mA family ratings for the selected probe.
  • Hazardous-area suitability must be documented for the actual supplied probe; the family source lists Ex ia IIB T4.

Engineering Note

Bare probes are individually pictured, but the source gives no variant-specific dimensions, wiring diagram or separate electrical table.

SIMEI FT-OP-160 — Optical overfill sensor probe
SIMEI FT-OP-160

Optical overfill sensor probe

Replacement or application-specific optical probe for the tanker bottom-loading overfill-prevention system.

Technical details

Main features

  • Detects liquid level during bottom loading and sends the signal to the loading-platform system.
  • Designed to support bottom-loading overfill prevention.
  • Probe length and material can be specified to suit the application.

Available Configurations

  • Straight probe with looped cable lead.
  • Probe length and material to user requirement

Technical & Ordering Data

Working voltage12 VDC
Working current<5 mA
Response time<1 s
Temperature range−20°C to +50°C
Working mediumLight fuel
Probe lengthMade to user requirement; confirm length
Seal materialConfirm before quotation
Probe materialConfirm before quotation
Electrical ratingsThe adjacent optical-sensor family table is the only table; confirm applicability to the selected bare probe.

Confirm Before Order

  • Confirm probe length, sensing tip, cable length, wiring, mounting and matched controller.
  • Confirm the 12 VDC / <5 mA family ratings for the selected probe.
  • Hazardous-area suitability must be documented for the actual supplied probe; the family source lists Ex ia IIB T4.

Engineering Note

Bare probes are individually pictured, but the source gives no variant-specific dimensions, wiring diagram or separate electrical table.

SIMEI FT-OP-170 — Overfill and grounding optic socket
SIMEI FT-OP-170

Overfill and grounding optic socket

Transfers the electrostatic-grounding and overfill signals between the tanker and the loading platform during bottom loading.

Technical details

Main features

  • Provides the tanker-to-platform signal interface for the overfill and grounding system.

Available Configurations

  • Square mounting plate, blue protective cap and tether pictured.

Technical & Ordering Data

InterfaceElectrical multi-contact socket
Pin arrangementConfirm before quotation
MaterialConfirm before quotation
Electrical ratingConfirm before quotation
Mounting dimensionsConfirm before quotation

Confirm Before Order

  • Confirm socket/plug standard, pinout, mounting pattern, cable connection and controller compatibility.

Engineering Note

The source provides two separate socket photographs and a shared function description, without dimensional or electrical ratings.

SIMEI FT-OP-180 — Overfill and grounding optic socket
SIMEI FT-OP-180

Overfill and grounding optic socket

Transfers the electrostatic-grounding and overfill signals between the tanker and the loading platform during bottom loading.

Technical details

Main features

  • Provides the tanker-to-platform signal interface for the overfill and grounding system.

Available Configurations

  • Rounded mounting flange and multi-contact socket pictured.

Technical & Ordering Data

InterfaceElectrical multi-contact socket
Pin arrangementConfirm before quotation
MaterialConfirm before quotation
Electrical ratingConfirm before quotation
Mounting dimensionsConfirm before quotation

Confirm Before Order

  • Confirm socket/plug standard, pinout, mounting pattern, cable connection and controller compatibility.

Engineering Note

The source provides two separate socket photographs and a shared function description, without dimensional or electrical ratings.

SIMEI FT-OP-190 — Tanker grounding bolt
SIMEI FT-OP-190

Tanker grounding bolt

Fits to the tanker chassis to detect the grounding connection for the bottom-loading system.

Technical details

Main features

  • Copper construction is described as corrosion-resistant and electrically conductive.

Available Configurations

  • Grounding bolt with blue cable pictured

Technical & Ordering Data

Bolt materialCopper
ConnectionChassis-mounted grounding detector
Thread and dimensionsConfirm before quotation
Cable lengthConfirm before quotation

Confirm Before Order

  • Confirm chassis mounting, thread, cable length and grounding-monitor compatibility.

Engineering Note

The source specifies copper but does not give a resistance limit, thread or dimensions for the standalone bolt.

SIMEI FT-OP-200 — Single-channel optical sensor tester
SIMEI FT-OP-200

Single-channel optical sensor tester

Checks connections and components of the tanker overfill-prevention system to verify that the connected system is functioning correctly.

Technical details

Main features

  • Single-channel tester configuration is pictured.
  • Supports checks of the optical overfill system connections and spare components.

Available Configurations

  • single tester configuration

Technical & Ordering Data

Test channels1
Test methodPortable electrical tester
Supply / batteryConfirm before quotation
Compatible sensor interfacesConfirm before quotation

Confirm Before Order

  • Confirm test functions, power supply, compatible wiring and included leads.

Engineering Note

The source distinguishes single and double testers but does not provide an electrical table or operating instructions.

SIMEI FT-OP-210 — Dual-channel optical sensor tester
SIMEI FT-OP-210

Dual-channel optical sensor tester

Checks connections and components of the tanker overfill-prevention system to verify that the connected system is functioning correctly.

Technical details

Main features

  • Dual-channel tester configuration is pictured.
  • Supports checks of the optical overfill system connections and spare components.

Available Configurations

  • dual tester configuration

Technical & Ordering Data

Test channels2
Test methodPortable electrical tester
Supply / batteryConfirm before quotation
Compatible sensor interfacesConfirm before quotation

Confirm Before Order

  • Confirm test functions, power supply, compatible wiring and included leads.

Engineering Note

The source distinguishes single and double testers but does not provide an electrical table or operating instructions.

SIMEI FT-OP-220 — Anti-overfill and static-grounding controller system
SIMEI FT-OP-220

Anti-overfill and static-grounding controller system

Integrated monitoring system for bottom loading that detects an overfill condition and checks the tanker-to-ground connection.

Technical details

Main features

  • Digital circuitry is described as resistant to interference.
  • Supports up to eight optical sensors and one grounding bolt.
  • Self-checking function.
  • Audible and visual alarm indicates the system operating state.
  • Relay output is available with open or closed contact options.
  • Plug and socket arrangement is described for API-style connections.
  • Compatibility with several other optical-sensor systems is claimed by the source and must be checked for the selected equipment.

Available Configurations

  • Main controller
  • Audible and visual alarm module
  • Coiled plug cable assembly
  • Return socket
  • Open / closed relay-output options

Technical & Ordering Data

Supply voltage220 VAC ±10%
Working current<20 mA
Response time<1 s
Ground resistance threshold<55 Ω
Enclosure protectionIP65; verify supplied assembly
Temperature rangeConfirm before quotation; source upper-limit typography is unreliable
Hazardous-area protectionConfirm certified protection for the actual supply
Relay output capacity5 A at 250 VAC or 5 A at 30 VDC, as stated in source text
Sensor capacityUp to 8 optical sensors plus 1 grounding bolt
Standard cable interface6-pin plug and coiled cable; pinout to confirm
Output parametersUo 16.5 V; Io 874 mA; Po 3.6 W; Co 1.8 µF; Lo 0.09 mH — verify as a matched set
Front drawing width / height270 / 230 mm
Front mounting reference185 mm
Side drawing width / height136 / 198 mm
Cable entry callout7 × G¾
Mounting corner calloutR5.5
Anti-overfill and static-grounding controller system — Main controller
Main controller
Anti-overfill and static-grounding controller system — Audible and visual alarm
Audible and visual alarm
Anti-overfill and static-grounding controller system — Coiled plug cable assembly
Coiled plug cable assembly
Anti-overfill and static-grounding controller system — Return socket
Return socket
Dimensions & Construction (2)

Drawings are selection references. Confirm dimensions, tolerances and interfaces against the approved drawing before manufacture.

Anti-overfill and static-grounding controller system — Original dimensional reference; verify dimensions before manufacture.
Original dimensional reference; verify dimensions before manufacture.
Anti-overfill and static-grounding controller system — Controller side elevation; dimensions in mm.
Controller side elevation; dimensions in mm.

Confirm Before Order

  • Source working-temperature upper limit is printed as 600°C; do not treat this as an operating rating. Obtain a confirmed temperature specification.
  • Verify applicable hazardous-area certification; source states Ex d(ia) IIB T4, which is not a SIMEI certification.
  • Verify the claimed API RP1004 / EN1392 interface compatibility and the exact intended standard designation.
  • Confirm compatibility, pinout and wiring for each sensor and loading-platform controller.
  • Verify the listed output safety parameters together and obtain the certified system drawing.

Engineering Note

The source power-supply row is mislabelled as working pressure. No pressure rating applies to this electrical controller. All protection and interoperability claims require order-specific documentation.

SIMEI ENERGY

Selection and ordering

Send the SIMEI code, quantity, transported medium, operating conditions and mating drawing. Confirm materials, seals, interfaces and operating requirements before ordering.

Related engineering

Tank terminal constructionFuel station equipment